AFFZP0BB – ACE3 – User Manual
Page – 115/139
26)
LIFT+LOWER
Cause:
Both the pump requests (LIFT and LOWER) are active at the same time.
Troubleshooting:
-
Check that LIFT and LOWER requests are not active at the same time.
-
Check the LIFT and LOWER input states through the TESTER function.
-
Check the wirings.
-
Check if there are failures in the microswitches.
-
If the problem is not solved, replace the logic board.
27)
WRONG SLAVE VER.
Cause:
Wrong software version on supervisor uC.
Troubleshooting:
Upload the correct software version or ask for assistance to a Zapi technician.
28)
SENS MOT TEMP KO
Cause:
The output of the motor thermal sensor is out of range.
Troubleshooting:
-
Check if the resistance of the sensor is what expected measuring its
resistance.
-
Check the wiring.
-
If the problem is not solved, replace the logic board.
29)
HW FAULT EB 01/02/03
Cause:
At start-up, the hardware circuit dedicated to enable and disable the EB driver
(A18) is found to be faulty.
Troubleshooting:
This type of fault is not related to external components. Replace the logic board.
30)
HW FAULT EV 01/02/04/08/10/20/40/80
Cause:
At start-up, the hardware circuit dedicate to enable and disable the EV drivers is
found to be faulty.
Troubleshooting:
This type of fault is not related to external components. Replace the logic board.
31)
WRONG ZERO
Cause:
At start-up the amplifiers used to measure the motor voltage sense voltages
above 3 V or below 2 V.
Содержание ACE3
Страница 14: ...Page 14 139 AFFZP0BB ACE3 User Manual 3 2 Connection drawing ACE3 Traction Standard...
Страница 15: ...AFFZP0BB ACE3 User Manual Page 15 139 3 3 Connection drawing ACE3 Traction Premium...
Страница 16: ...Page 16 139 AFFZP0BB ACE3 User Manual 3 4 Connection drawing ACE3 Pump Standard...
Страница 17: ...AFFZP0BB ACE3 User Manual Page 17 139 3 5 Connection drawing ACE3 Pump Premium...