SET OPTIONS
Parameter
Allowable range
Description
STEERING TYPE
(T, TM)
NONE ÷ ANALOG
This parameter defines which type of steering unit is
connected to the controller.
NONE =
steering module is not present on the truck; ACE3
does not wait for any CAN message from the EPS and it
does not apply EPS and braking steering cutback.
OPTION#1 =
EPS is present and it is configured with
e toggle switches, whose signals are acquired
and related data transmitted to ACE3 via CAN bus.
OPTION#2 =
EPS is present and it is configured with
potenti encoder, whose signals are acquired and
related data transmitted to ACE3 via CAN bus.
ANALOG =
A hydraulic steering is adopted and ACE3
acquires through one of its analog inputs the signal coming
from a steering potentiometer, as a feedback of the
steering orientation.
M.C. FUNCTION
(T, TM, P, CO)
OFF ÷ OPTION#2
This parameter defines the configuration for the main contactor
or line contactor output (A16, NLC: Negative Line Contactor).
OFF =
main contactor is not present. Diagnoses are
masked and MC is not driven.
ON =
main contactor is in standalone configuration.
Diagnoses are performed and MC is closed after key-on
only if they have passed.
OPTION#1 =
for a traction & pump setup, with only one
main contactor for both controllers. Diagnoses are
performed and MC is closed after key-on only if they have
passed.
OPTION#2 =
for a traction & pump setup, with two main
contactors. Each controller drives its own MC. Diagnoses
are performed and MCs are closed after key-on only if they
have passed.
EBRAKE ON APPL.
(T, TM, P, CO)
ABSENT, PRESENT
This parameter enables or disables the management of the
electromechanical brake:
ABSENT =
the diagnosis are masked and E.B. is not
driven upon a traction request.
PRESENT =
E.B. is driven upon a traction request if all the
related diagnosis pass.
AUX OUT FUNCTION
(A)
NONE, BRAKE
This parameter enables or disables the output A18 (NEB):
NONE =
the diagnosis are masked and E.B. is not driven
upon a traction request.
BRAKE =
E.B. is driven upon a traction request if all the
related diagnosis pass. The behavior on a slope depends
on the “STOP ON RAMP” setting (see “Behavior on a
slope” table at the end of the paragraph).
SYNCRO
(CO)
OFF, ON
This parameter enables or disables the syncro message.
OFF =
the Syncro message is not used.
ON =
the Syncro message is enabled.
Содержание ACE3
Страница 14: ...Page 14 139 AFFZP0BB ACE3 User Manual 3 2 Connection drawing ACE3 Traction Standard...
Страница 15: ...AFFZP0BB ACE3 User Manual Page 15 139 3 3 Connection drawing ACE3 Traction Premium...
Страница 16: ...Page 16 139 AFFZP0BB ACE3 User Manual 3 4 Connection drawing ACE3 Pump Standard...
Страница 17: ...AFFZP0BB ACE3 User Manual Page 17 139 3 5 Connection drawing ACE3 Pump Premium...