Page – 132/139
AFFZP0BB – ACE3 – User Manual
From top:
First line tells which firmware version is running inside the console, in this case
ZP 0.15.
RS232 Console: enter this menu to start a serial connection as in the Console
Ultra.
CAN Console: enter this menu to establish a CAN connection.
AUTOSCAN CAN: another way to establish a CAN connection.
Console Utilities and Menu Console: ignore them at the moment.
The current hour is shown at the bottom right.
Moreover, the green LED is on and still.
The “RS232” line is already highlighted at the start-up. Press OK key to start a serial
connection.
Display prompts a message to inform you that a connection attempt is ongoing.
If serial connection fails a “NO COMMUNICATION” warning will be shown after
some seconds: press ESC key and look for what is preventing the connection.
4
Please notice the red dot appearing on the top right of the display every time you
press a button. It indicates that the console has received the command and it is
elaborating the request. If the red dot does not appear when a button is pressed,
there is probably a failure inside the keyboard or the console has stalled.
12.2.4 Connected
If connection is successful, the display will show a page similar to the next one.
This menu shows basic information about the controller, in a similar way to the
console Ultra.
First line displays the controller firmware.
Second line shows controller voltage, controller current and hour meter.
Last line shows the current alarm code, if present.
Press OK to access the MAIN MENU.
Содержание ACE3
Страница 14: ...Page 14 139 AFFZP0BB ACE3 User Manual 3 2 Connection drawing ACE3 Traction Standard...
Страница 15: ...AFFZP0BB ACE3 User Manual Page 15 139 3 3 Connection drawing ACE3 Traction Premium...
Страница 16: ...Page 16 139 AFFZP0BB ACE3 User Manual 3 4 Connection drawing ACE3 Pump Standard...
Страница 17: ...AFFZP0BB ACE3 User Manual Page 17 139 3 5 Connection drawing ACE3 Pump Premium...