AFFZP0BB – ACE3 – User Manual
Page – 87/139
Error code
Effect
Condition
Restart
procedure
CAN
OPEN
CODE
MDI
CODE
ZAPI
CODE
LED
CODE
VDC LINK OVERV.
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Stand-by, running
Valves or
Traction/Pump
Request
0XFFCA
77
202
77
EB is applied,
Traction/Pump, valves
stopped
re-cycle
SEAT MISMATCH
MC is not closed,
EB is applied,
Traction/Pump stopped
Start-up, stand-by,
running
Valves or Traction/
Pump request
0xFFDE
15
222
15
LOGIC FAILURE #1
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Stand-by, running
Valves or
Traction/Pump
Request
0x5114
19
19
19
LOGIC FAILURE #2
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by,
Valves or
Traction/Pump
Request
0XFF12
18
18
18
LOGIC FAILURE #3
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by
Valves or
Traction/Pump
Request
0XFF11
17
17
17
LC COIL OPEN
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
Request
0xFFE6
22
230
22
IQ MISMATCHED
Traction is stopped
Running
Valves or
Traction/Pump
Request
0xFFF5
24
245
24
INIT VMN LOW 01
INIT VMN LOW 02
INIT VMN LOW 03
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up Key
re-cycle
0x3121
30
207
30
INIT VMN HIGH 81
INIT VMN HIGH 82
INIT VMN HIGH 83
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up
Key re-cycle
0x3111
31
206
31
VMN HIGH
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by
Valves or
Traction/Pump
Request
0x3110
31
31
31
VMN LOW
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up
Valves or
Traction/Pump
Request
0x3120
30
30
30
HW FAULT 11
HW FAULT 12
HW FAULT 13
MC is not closed,
EB is applied,
Traction/Pump stopped
Start-up Key
re-cycle
0xFFE3
32
227
32
HW FAULT 01
HW FAULT 02
HW FAULT 03
MC is not closed,
EB is applied,
Traction/Pump stopped
Start-up Key
re-cycle
0xFFE3
32
227
32
POSITIVE LC OPEN
MC is not closed,
EB is applied,
Traction/Pump, valves
stopped
Start-up, stand-by,
running
Key re-cycle
0xFFD5
35
213
35
FIELD ORIENT KO
MC is opened, EB is
applied, Traction/Pump,
valves stopped
Running
Valves or
Traction/Pump
0xFFFD
36
253
36
Содержание ACE3
Страница 14: ...Page 14 139 AFFZP0BB ACE3 User Manual 3 2 Connection drawing ACE3 Traction Standard...
Страница 15: ...AFFZP0BB ACE3 User Manual Page 15 139 3 3 Connection drawing ACE3 Traction Premium...
Страница 16: ...Page 16 139 AFFZP0BB ACE3 User Manual 3 4 Connection drawing ACE3 Pump Standard...
Страница 17: ...AFFZP0BB ACE3 User Manual Page 17 139 3 5 Connection drawing ACE3 Pump Premium...