Page – 50/139
AFFZP0BB – ACE3 – User Manual
SET OPTIONS
Parameter
Allowable range
Description
AUTO PARK BRAKE
(CO)
OFF, ON
This parameter enables or disables the autonomous
management of the brake.
OFF =
E.B. is activated or deactivated according to the
signal received via CAN bus.
ON =
E.B. is managed by the controller itself ignoring any
activation/deactivation signal received via CAN bus.
AUTO LINE CONT.
(CO)
OFF, ON
This parameter enables or disables the autonomous
management of the main contactor.
OFF =
main contactor is opened or closed according to the
signals received by CAN bus.
ON =
main contactor is managed by the controller itself
ignoring any activation/deactivation signal received via
CAN bus.
ACCEL MODULATION
(T, TM, P, CO)
OFF, ON
This parameter enables or disables the acceleration-
modulation function.
OFF =
the acceleration rate is inversely proportional to the
ACCEL DELAY parameter.
ON =
the acceleration ramp is inversely proportional to the
ACCEL DELAY parameter only if speed setpoint is greater
than 100 Hz. Below 100 Hz the acceleration ramp is also
proportional to the speed setpoint, so that the acceleration
duration results equal to ACCEL DELAY.
See paragraph 8.4.
EVP TYPE
(A)
NONE ÷ DIGITAL
This parameter defines how the output A19 (EVP) operates.
NONE =
output not enabled, no load connected to A19.
ANALOG =
A19 manages a current-controlled
PWM-modulated proportional valve.
DIGITAL =
A19 manages an on/off valve.
See the EVP-related parameters in PARAMETER CHANGE.
EV1
(A – Premium version
only)
ABSENT, OPTION#2
This parameter defines how the output B16 (NEV1) operates.
ABSENT =
output not enabled, no on B16.
OPTION#1 =
B16 manages an on/off valve. By default it is
controlled by the 1
st
-speed command.
OPTION#2 =
free for future use.
EV2
(A – Premium version
only)
ABSENT, DIGITAL
This parameter defines how the output B17 (NEV2) operates.
ABSENT =
output not enabled, no on B17.
DIGITAL =
B17 manages a voltage-controlled PWM-
modulated valve. The PWM frequency is 1kHz and the
duty cycle depends on PWM EV2 (ADJUSTMENT list).
EV3
(A – Premium version
only)
ABSENT, DIGITAL
This parameter defines how the output B18 (NEV3) operates.
ABSENT =
output not enabled, no load on
B18.
DIGITAL =
B18 manages a voltage-controlled PWM-
modulated valve. The PWM frequency is 1kHz and the
duty cycle depends on PWM EV3 (ADJUSTMENT list).
Содержание ACE3
Страница 14: ...Page 14 139 AFFZP0BB ACE3 User Manual 3 2 Connection drawing ACE3 Traction Standard...
Страница 15: ...AFFZP0BB ACE3 User Manual Page 15 139 3 3 Connection drawing ACE3 Traction Premium...
Страница 16: ...Page 16 139 AFFZP0BB ACE3 User Manual 3 4 Connection drawing ACE3 Pump Standard...
Страница 17: ...AFFZP0BB ACE3 User Manual Page 17 139 3 5 Connection drawing ACE3 Pump Premium...