AFFZP0BB – ACE3 – User Manual
Page – 69/139
7.3.2 Supervisor
microcontroller
The following table lists the supervisor microcontroller data that can be monitored
through the TESTER function.
TESTER (Supervisor)
Parameter
Unit of measure
(resolution)
Description
MEASURED SPEED
(A)
Hertz (0.1 Hz)
Motor speed measured through the encoder and
expressed in the same unit of FREQUENCY (Hz).
A4
(A)
OFF/ON
Status of input A4.
A5
(A)
OFF/ON
Status of input A5.
A11
(A)
OFF/ON
Status of input A11.
B13
(A)
OFF/ON
Status of input B13.
B6
(A)
OFF/ON
Status of input B6.
B4
(A)
OFF/ON
Status of input B4.
B5
(A)
OFF/ON
Status of input B5.
B11
(A)
OFF/ON
Status of input B11.
A13
(A)
OFF/ON
Status of input A13.
A3 POT#1
(A)
Volt (0.01V)
Voltage of analog input A3.
A10 POT#2
(A)
Volt (0.01V)
Voltage of analog input A10.
B2 POT#3
(A)
Volt (0.01V)
Voltage of analog input B2.
B10 POT#4
(A)
Volt (0.01V)
Voltage of analog input B10.