Command Function
Page
:SWEep
:SPACing/?
Sets the sweep type (linear or log) or queries the current setting.
16-18
:STARt/?
Sets the voltage sweep start value or queries the current setting.
16-18
:STOP/?
Sets the voltage sweep stop value or queries the current setting.
16-19
:STEP/?
Sets the linear voltage sweep resolution or queries the current setting.
16-19
:POINts/?
Sets the number of divisions of the voltage log sweep or queries the
current setting.
16-19
:PULSe
:WIDTh/?
Sets the pulse width for pulse width mode or queries the current setting. 16-19
:BASE/?
Sets the pulse base value for voltage pulse source mode or queries the
current setting.
16-20
:ZERO
:IMPedance/?
Sets the impedance (high or low) for voltage zero source or queries the
current setting.
16-20
[:CURRent]
:RANGe/?
Sets the current source range or queries the current setting.
16-20
:AUTO/?
Turns ON/OFF the auto current source range or queries the current
setting. 16-20
:LEVel/?
Sets the current source level or queries the current setting.
16-21
:PROTection
[:STATe]/?
Turns ON/OFF the limiter function or queries the current setting.
16-21
:LINKage/?
Turns ON/OFF the limiter tracking function or queries the current setting. 16-21
:LEVel/?
Sets the current limit (for voltage source mode) or queries the current
setting. 16-21
:UPPer/?
Sets the current upper limit (for voltage source mode) or queries the
current setting.
16-22
:LOWer/?
Sets the current lower limit (for voltage source mode) or queries the
current setting.
16-22
:SWEep
:SPACing/?
Sets the sweep type (linear or log) or queries the current setting.
16-22
:STARt/?
Sets the current sweep start value or queries the current setting.
16-22
:STOP/?
Sets the current sweep stop value or queries the current setting.
16-23
:STEP/?
Sets the linear current sweep resolution or queries the current setting.
16-23
:POINts/?
Sets the number of divisions of the current log sweep or queries the
current setting.
16-23
:PULSe
:WIDTh/?
Sets the pulse width for pulse width mode or queries the current setting. 16-23
:BASE/?
Sets the pulse base value for current pulse source mode or queries the
current setting.
16-24
:ZERO
:IMPedance/?
Sets the impedance (high or low) for current zero source or queries the
current setting.
16-24
Measurement Commands (SENSe Group)
[:CHANnel<n>]
:SENSe
[:STATe]/?
Turns ON/OFF the measurement function or queries the current setting. 16-25
:MODE/?
Sets the measurement mode (fixed function, auto function, voltmeter,
ammeter, or resistance meter) or queries the current setting.
16-25
:TRIGger/?
Sets the measurement trigger source (source change, sweep end,
auxiliary trigger, Timer1, Timer2, or immediate) or queries the current
setting. 16-25
:AUXiliary
:POLarity/?
Sets the auxiliary trigger polarity (normal or inverted) or queries the
current setting.
16-25
16-8
IM 765601-01E
16.2 Commands