6. Programming Features
85
* Reduction of the current is not necessary.
1. Reduce the continuous output current when changing the
carrier frequency to 4 (10 kHz) for 200 V Class (1.5 kW
or more) and 400 V Class Inverters. Refer to the table
above for the reduced current.
Operation Condition
• Input power supply voltage:
3-phase 200 to 230 V (200 V Class)
Single-phase 200 to 240 V (200 V Class)
3-phase 380 to 460 V (400 V Class)
• Ambient temperature:
−
10 to 50
°
C
(Protection structure: open chassis type IP20,
IP00)
−
10 to 40
°
C
(Protection structure: enclosed wall-mounted type
NEMA 1 (TYPE 1))
200 V
Single-
phase or
3-phase
5.5
3
7.5
25
23
7.5
3
7.5
33
30
400 V
3-phase
0.2
3
7.5
1.2
1.0
0.4
3
7.5
1.8
1.6
0.75
3
7.5
3.4
3.0
1.5
3
7.5
4.8
4.0
2.2
3
7.5
5.5
4.8
3.0
3
7.5
7.2
6.3
3.7
3
7.5
8.6
8.1
5.5
3
7.5
14.8
*
7.5
3
7.5
18
17
Voltage
Class (V)
Capacity
(kW)
Factory Setting
Maximum
Continuous
Output Current
(A)
Reduced
Current
(A)
Setting Carrier Frequency
(kHz)
NOTE