
9. Specifications
201
018
0112
Selecting Setting Unit for Ac-
celeration/deceleration Time
0, 1
-
0
No
72
019
0113
Acceleration Time 1
0.00 to 6000 s Depend on
n018 setting
10.0 s
Yes
71
020
0114
Deceleration Time 1
0.00 to 6000 s Depend on
n018 setting
10.0 s
Yes
71
021
0115
Acceleration Time 2
0.00 to 6000 s Depend on
n018 setting
10.0 s
Yes
71
022
0116
Deceleration Time 2
0.00 to 6000 s Depend on
n018 setting
10.0 s
Yes
71
023
0117
S-curve Selection
0 to 3
-
0
No
73
024
0118
Frequency Reference 1 (Mas-
ter Frequency Reference)
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
6.00 Hz
Yes
67
025
0119
Frequency Reference 2
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz
Yes
67
026
011A
Frequency Reference 3
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz
Yes
67
027
011B
Frequency Reference 4
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz
Yes
67
028
011C
Frequency Reference 5
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz
Yes
67
029
011D
Frequency Reference 6
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz
Yes
67
030
011E
Frequency Reference 7
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/
0.1 Hz (100
Hz or more)
0.00 Hz
Yes
67
No. Register
No. for
Trans-
mission
Name
Setting Range Setting Unit
Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page