9. Specifications
211
* 1. Values are doubled for 400 V Class.
* 2. 10.0 V for 5.5 kW and 7.5 kW Inverters of 200-V Class and 20.0 V of
400-V Class.
Factory Settings That Change with the Inverter Capacity
• 200 V Class 3-phase
* Sets the value of the motor resistance for one phase.
No.
Name
V/f Control
Mode
(n002 = 0)
Vector Con-
trol Mode
(n002 = 1)
n014
Mid. Output Frequency
1.5 Hz
3.0 Hz
n015
Mid. Output Frequency Voltage
12.0 V
*1
*2
11.0 V
*1
n016
Min. Output Frequency
1.5 Hz
1.0 Hz
n017
Min. Output Frequency Voltage
12.0 V
*1
*2
4.3 V
*1
n104
Torque Compensation Time Constant
0.3 s
0.2 s
n111
Slip Compensation Gain
0.0
1.0
n112
Slip Compensation Gain Time Constant
2.0 s
0.2 s
No.
Name
Unit
Factory Setting
-
Inverter Capacity
kW
0.1
kW
0.2
kW
0.4
kW
0.75
kW
1.5
kW
2.2
kW
3.7
kW
5.5
kW
7.5
kW
n036 Motor Rated Current
A
0.6
1.1
1.9
3.3
6.2
8.5
14.1 19.6 26.6
n105 Torque Compensation
Iron Loss
W
1.7
3.4
4.2
6.5
11.1
11.8
19
28.8 43.9
n106 Motor Rated Slip
Hz
2.5
2.6
2.9
2.5
2.6
2.9
3.3
1.5
1.3
n107 Motor Line-to-neutral
Resistance*
Ω
17.99 10.28 4.573 2.575 1.233 0.8 0.385 0.199 0.111
n108 Motor Leakage
Inductance
mH 110.4 56.08 42.21 19.07 13.4 9.81 6.34 4.22 2.65
n110 Motor No-load
Current
%
72
73
62
55
45
35
32
26