200
Constants List
• Addition of Constants Accompanied by the Upgraded Software
Version
#1: Applicable for software version Nos.VSP010028, VSP010106 or
later.
First Functions (Constants n001 to n049)
No. Register
No. for
Trans-
mission
Name
Setting Range Setting Unit
Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page
001 0101H Password
0 to 6, 8, 9
-
1
No
55
002
0102
Control Mode Selection (Note
6)
0, 1
-
0
(Note 1)
No
60
003
0103
RUN Command Selection
0 to 3
-
0
No
65
004
0104
Frequency Reference Selec-
tion
0 to 9
-
0
(Note 5)
No
66
005
0105
Stopping Method Selection
0, 1
-
0
No
87
006
0106
Reverse Run Prohibit
0, 1
-
0
No
67
007
0107
Stop Key Selection
0, 1
-
0
No
86
008
0108
Frequency Reference Selec-
tion in Local Mode
0, 1
-
0
(Note 5)
No
66
009
0109
Frequency Reference Setting
Method From Digital Operator
0, 1
-
0
No
66
010
010A
Detecting Fault Contact of
Digital Operator
0, 1
-
0
No
65
011
010B
Max. Output Frequency
50.0 to 400.0
Hz
0.1 Hz
60.0 Hz
No
57
012
010C
Max. Voltage
0.1 to 255.0 V
(Note 2)
0.1 V
200.0 V
(Note 2)
No
57
013
010D
Max. Voltage Output
Frequency
0.2 to 400.0 Hz
0.1 Hz
60.0 Hz
No
57
014
010E
Mid. Output Frequency
0.1 to 399.9 Hz
0.1 Hz
1.5 Hz
(Note 6)
No
57
015
010F
Mid. Output Frequency Volt-
age
0.1 to 255.0 V
(Note 2)
0.1 V
12.0 V
(Note 2,
6)
No
57
016
0110
Min. Output Frequency
0.1 to 10.0 Hz
0.1 Hz
1.5 Hz
(Note 6)
No
57
017
0111
Min. Output Frequency Volt-
age
0.1 to 50.0 V
(Note 2)
0.1 V
12.0 V
(Note 2,
6)
No
57