9. Specifications
205
Third Functions (Constants n080 to n119)
No. Register
No. for
Trans-
mission
Name
Setting Range Setting Unit
Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page
080
0150
Carrier Frequency Selection
1 to 4, 7 to 9
-
(Note 4)
No
83
081
0151
Momentary Power Loss
Ridethrough Method
0 to 2
(Note 10)
-
0
No
72
082
0152
Automatic Retry Attempts
0 to 10 times
-
0
No
77
083
0153
Jump Frequency 1
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz
No
76
084
0154
Jump Frequency 2
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz
No
76
085
0155
Jump Frequency 3
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz
No
76
086
0156
Jump Frequency Range
0.00 to
25.50 Hz
0.01 Hz
0.00
Hz
No
76
087
0157
Cumulative operation time
function selection
(Note 9)
0, 1
-
0
No
-
088
0158
Cumulative operation time
(Note 9)
0 to 6550
1 = 10H
0H
No
-
089
0159
DC Injection Braking Current
0 to 100%
1%
50%
No
78
090
015A
DC Injection Braking Time at
Stop
0.0 to 25.5 s
0.1 s
0.5 s
No
88
091
015B
DC Injection Braking Time at
Startup
0.0 to 25.5 s
0.1 s
0.0 s
No
78
092
015C
Stall Prevention During Decel-
eration
0, 1
-
0
No
105
093
015D
Stall Prevention Level During
Acceleration
30% to 200%
1%
170%
No
102
094
015E
Stall Prevention Level During
Running
30% to 200%
1%
160%
No
105
095
015F
Frequency Detection Level
0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz
No
75