5. Operating the Inverter
53
Data setting by frequency setting potentiometer
Operation Steps
Operator
Display
Function
Indicators
Status
Indicators
1. Turn ON the power supply.
0.00
2. Press
to make
lit, then
set constant n004 to 1.
1
3. Set the following constants.
n019: 15.0 (acceleration time)
n020: 5.0 (deceleration time)
15.0
5.0
4. Press
to make
lit, then
select forward or reverse run by press-
ing
or
key.
Examine the application. (Never
select REV when reverse run is
prohibited.)
(Forward)
or
(Reverse)
5. Press
to make
lit, then
set the reference by pressing
or
key.
60.00
6. Press
to make
lit, then
press .
0.00
→
60.00
7. Press
to stop.
60.00
→
0.00