Index:Sub
Name
Type
Offset
Access Default
Description
0x7000...
0x703F:00
Output data
U8
0
ro
60
Number of subindexes of the output data for the
corresponding EtherCAT-Slot.
0x7000...
0x703F:01
U32
16
ro
Output data (see module description)
0x7000...
0x703F:02
U32
ro
0x7000...
0x703F: ...
...
...
ro
‘Explanation of the elements’ page 82
Please note that in operation mode Enhanced Mode the index of the
module-related objects is to be incremented accordingly.
The index is calculated as follows:
Index
Enhanced
= Index + (16
EtherCAT-Slot)
Chap. 4.3 ‘Operating Mode - Normal/Enhanced mode’ page 58
n
With this object the output data of a System SLIO may be read.
n
Here the addressing via index ( EtherCAT-Slot) takes place.
n
The corresponding output data may be accessed via subindexes.
–
The allocation of the subindexes may be found in the description of the corre-
sponding module.
Information concerning the write access to outputs may be found in the
manual of your EtherCAT master.
Read output data