Code
Description
Current State
Resulting State
0x0032
PLL Error
O, S > O
S + E
0x0033
DC Sync IO Error
O, S > O
S + E
0x0034
DC Sync Timeout Error
O, S > O
S + E
0x0035
DC Invalid Sync Cycle Time
P > S
P + E
0x0036
DC Sync0 Cycle Time
P > S
P + E
0x0037
DC Sync1 Cycle Time
P > S
P + E
0x0041
MBX_AOE
B, P, S, O
Current state + E
0x0042
MBX_EOE
B, P, S, O
Current state + E
0x0043
MBX_COE
B, P, S, O
Current state + E
0x0044
MBX_FOE
B, P, S, O
Current state + E
0x0045
MBX_SOE
B, P, S, O
Current state + E
0x004F
MBX_VOE
B, P, S, O
Current state + E
0x0050
EEPROM No Access
Any
Any + E
0x0051
EEPROM Error
Any
Any + E
0x0060
Coupler Restarted Locally
Any
I
< x8000
Reserved
4.10.3.1
SyncManager watchdog
If there is no communication to the master possible e.g. line is interrupted, you will get the
error message 0x001B after the SyncMaster watchdog time has been elapsed. The time
is to be configured in the master.
n
SyncManager watchdog is used for "frame monitoring"
–
If no more frames arrive to the slave in a certain time, it comes to the watchdog
and the slave changes to SafeOp with the AlStatusCode 0x001B
n
By default, the SyncManager watchdog is always active with a time of 100ms
n
Changing in the parameters e.g. via the EtherCAT Manager is changed once and
remains valid until new values are received. The values are not stored remanently
n
Time from the SyncManager watchdog should always be greater than the set bus
cycle time at the EtherCAT Master. Since the SyncManager watchdog is always trig-
gered when a process data frame is received
n
If parameterized, substitute values are displayed for the modules
4.10.4
SDO error code
If a SDO request is negative evaluated, an according SDO error code is released. In the
following table the possible errors are listed.
Code
Description
0x05030000
Toggle bit not alternated
0x05040000
SDO protocol timed out
0x001B
System SLIO
Deployment
Error handling > SDO error code
HB300 | IM | 053-1EC01 | en | 22-30
108