SIEP C730600 84G DeviceNet Technical Manual
29
No.
(Hex.)
Name
Description
Default
(Range)
Note:
When you set
F6-08
to
1
and you then use
A1-03
to initialize the drive, the drive will not
change this setting value.
F6-15
(0B5B)
Comm. Option Parameters
Reload
Sets how the drive will enable the
F6-xx/F7-xx
communication-related parameters that you
changed.
0 : Reload at Next Power Cycle
1 : Reload Now
2 : Cancel Reload Request
Note:
•
F6-15
is reset to
0
after setting
1
or
2
.
•
Available in option software versions 1115 and later. Not available on 1000-series drives.
0
(0 - 2)
F6-50
(03C1)
DeviceNet MAC Address
Selects the drive MAC address.
Note:
•
All MAC addresses must be unique. Make sure that you do not use the setting MAC address
for another node.
•
Cycle power for setting changes to take effect.
•
The default setting depends on region code.
Default by region code (Example: CIMR-Vx or GA70x):
–
0: A (Japan), B (China), C (Europe), D (India), K (Korea), T (Asia)
–
64: U (The Americas)
0
(0 - 64)
F6-51
(03C2)
DeviceNet Baud Rate
0 : 125 kbps
1 : 250 kbps
2 : 500 kbps
3 : Adjustable from Network
4 : Detect Automatically
Note:
•
Cycle power for setting changes to take effect.
•
The default setting depends on region code.
Default by region code (Example: CIMR-Vx or GA70x):
–
0: A (Japan), B (China), C (Europe), D (India), K (Korea), T (Asia)
–
64: U (The Americas)
0
(0 - 4)
F6-52
(03C3)
DeviceNet PCA Setting
Sets the format of data that the DeviceNet communication master sends to the drive.
Note:
If
F6-52 [DeviceNet PCA Setting]
and
F6-53 [DeviceNet PPA Setting]
are not correct, the
value is reset to default.
21
(0 - 255)
F6-53
(03C4)
DeviceNet PPA Setting
Sets the format of data that the drive sends to the DeviceNet communication master.
Note:
If
F6-52 [DeviceNet PCA Setting]
and
F6-53 [DeviceNet PPA Setting]
are not correct, the
value is reset to default.
71
(0 - 255)
F6-54
(03C5)
Net Idle Fault Detection
Determines what the drive should do when communication goes into idle mode.
0 : Enabled
1 : Disabled, No Fault Detection
2 : Vendor Specific
3 : RUN Forward
4 : RUN Reverse
Note:
•
Cycle power for setting changes to take effect.
•
When setting
2
, drive will use to
F6-01 [Communication Error Selection]
to determine
whether it should stop or continue.
0
(0 - 4)
F6-55
(03C6)
DeviceNet Baud Rate
Monitor
Displays the baud rate currently being used for network communications. F6-55 is used only as a
monitor.
0 : 125 kbps
1 : 250 kbps
2 : 500 kbps
0
(0 - 2)
F6-56
(03D7)
DeviceNet Speed Scaling
Sets the scaling factor for the Speed Monitor in the DeviceNet Object Class 2A hex.
0
(-15 - +15)
F6-57
(03D8)
DeviceNet Current Scaling
Sets the current scale of the DeviceNet communication master.
0
(-15 - +15)
F6-58
(03D9)
DeviceNet Torque Scaling
Sets the torque scale of the DeviceNet communication master.
0
(-15 - +15)
F6-59
(03DA)
DeviceNet Power Scaling
Sets the power scale of the DeviceNet communication master.
0
(-15 - +15)
F6-60
(03DB)
DeviceNet Voltage Scaling
Sets the voltage scale of the DeviceNet communication master.
0
(-15 - +15)
F6-61
(03DC)
DeviceNet Time Scaling
Sets the time scale of the DeviceNet communication master.
0
(-15 - +15)
F6-62
(03DD)
DeviceNet Heartbeat
Interval
Sets the heartbeat interval. A setting of 0 disables the heartbeat function.
0
(0 - 10)