Sigma II User’s Manual
Appendix B: List of Parameters
B - 20
B.7 List of Added & Changed Parameters
This chapter explains about the parameters, monitors, functions, and alarms added and/or
changed for SGDH in versions 33
or higher.
B.7.1 Parameter list
Note: The changed part in the parameter changed is highlighted in gray
Category
Parameter
Name
Unit
Lower
Limit
Upper
Limit
Factory
Setting
Function
selection
parameters
Pn080
Function selec-
tion base switch
(Linear motor
only)
–
0000H
1011H
0000H
Gain related
parameters
Pn103
Inertia ratio
%
0
20000
0
Pn10B
Gain related
application
switch
–
0000H
2314H
0000H
Position related
par
a
meters
Pn207
Position control
function switch
–
0000H
1111H
0000H
Pn212
Dividing ratio
pulse
00002048
00262144
2048
Pn217
Reference pulse
input
magnification
×1
1
99
1
Pn218
Reference pulse
magnification
function selection
–
0000H
0001H
0000H
Pn281
PG dividing ratio
(Linear motor
only
pulse/
Scale
pitch
1
255
20
Speed
related
parameters
Pn384
Motor peak speed
(Linear motor
only)
100mm/s
1
100
50
Torque
related
parameters
Pn408
Torque related
function switch
–
0000H
0101H
0000H
Pn40A
Notch filter Q
value
×0.01
50
400
70
Pn40B
Notch filter two
frequencies
Hz
50
2000
2000
Pn40C
Notch filter two Q
value
×0.01
50
400
70
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......