Sigma II User’s Manual
Chapter 8: Ratings and Characteristics
8 - 34
Specifications for Servo Amplifier and Three-phase, 400V
Servomotor Combinations
*1
Allowable regenerative frequency is the number of times the servomotor is allowed to accelerate and
decelerate through a 0rpm
→
maximum motor speed
→
0rpm cycle in a minute.
Voltage
Three-phase 400V
Servo Amplifier Model
SGDH-
05DE
10DE
15DE
20DE
30DE
50DE
60DE
75DE
1ADE
1EDE
SG
MG
H
S
er
ies
Appl
ica
ble
Se
rv
om
ot
or
Model
SGMGH-
05D
09D
13D
20D
30D
44D
55D
75D
1AD
1ED
Capacity
(kW)
0.45
0.85
1.3
1.8
2.9
4.4
5.5
7.5
11
15
Motor Speed
(rpm)
Rated 1500/maximum 3000
Rated 1500/
maximum 2000
Applicable Encoder
Standard: 17-bit incremental encoder
Continuous Output
Current
A
rms
1.9
3.5
5.4
8.4
11.9
16.5
20.8
25.4
28.1
37.2
Maximum Output Current
A
rms
5.5
8.5
14
20
28
40.5
55
65
70
85
Allowable Regenerative
Frequency
*1
(times/min)
42
15
10
12
8
11
26
18
36
32
SGMSH Series
Appl
ica
ble
Se
rv
om
ot
or
Model
SGMSH-
—
10D
15D
20D
30D
40D
50D
—
Capacity
(kW)
—
1.0
1.5
2.0
3.0
4.0
5.0
—
Motor Speed
(rpm)
Rated 3000/maximum 5000
Applicable Encoder
Standard: 17-bit incremental encoder
Continuous Output
Current
A
rms
—
2.8
4.7
6.2
8.9
12.5
13.8
—
Maximum Output Current
A
rms
—
8.5
14
19.5
28
38
42
—
Allowable Regenerative
Frequency
*
(times/min)
—
47
31
48
20
29
22
—
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......