![YASKAWA SGMAH Скачать руководство пользователя страница 455](http://html.mh-extra.com/html/yaskawa/sgmah/sgmah_user-manual_3716675455.webp)
Sigma II User’s Manual
Appendix B: List of Parameters
B - 19
B.6 Monitor Modes
The following list shows monitor modes available
Parameter
Content of Display
Unit
Remarks
Un000
Actual motor speed
rpm
—
Un001
Input speed reference
rpm
—
Un002
Internal torque reference
%
Value for rated torque
Un003
Rotation angle 1
pulse
Number of pulses from the origin
Un004
Rotation angle 2
degree
Angle from the origin (electrical angle)
Un005
Input signal monitor
—
—
Un006
Output signal monitor
—
—
Un007
Input reference pulse speed
rpm
—
Un008
Error counter value
reference units
Amount of position error
Un009
Accumulated load rate
%
Value for the rated torque
Displays in 10s cycle.
Un010
Allowable maximum motor speed/
dividing ratio
100 mm/s or
Pulse/scale
pitch
(
Pn280
)
Displays in decimal codes.
Un011
Hall sensor signals
–
–
Un00A
Regenerative load rate
%
Value for the processable regenerative
power
Displays in 10s cycle.
Un00B
Power consumed by DB resistance
%
Value for the processable power when
dynamic brake is applied
Displays in 10s cycle.
Un00C
Input reference pulse counter
—
Displayed in hexadecimal.
Un00D
Feedback pulse counter
—
Displayed in hexadecimal.
Un100~
UN104
Reserved
—
—
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......