Sigma II User’s Manual
Chapter 4: Trial Operation
4 - 10
4.2 Additional Setup Procedures in Trial Operation
Before starting trial operation, precautionary setup procedures must be followed when
either of two equipment configurations are used. These are delineated in the two
subsequent sections.
4.2.1
Servomotors with Brakes
Use a servomotor with a brake for vertical shaft applications or when external force
must be applied to the shaft to prevent rotation due to gravity or external force
during a power loss.
The servo amplifier uses the brake interlock output (/BK) signal to control the
holding brake operation when using servomotors with brakes.
Note: To prevent faulty operation due to gravity or external force, first make sure that both the servomotor
and holding brake work properly when . When assured that each operates properly, connect the
servomotor to the rest of the equipment to start the trial operation.
The following figure shows wiring for a servomotor with brakes. See
5.4.4 Using
the Holding Brake
for details on wiring.
Holding brake
Prevents the
servomotor from
rotating due to gravity.
External
force
Servomotor
Servomotor
•
Vertical shaft
•
Shaft with external force applied
Power supply
Three-Phase 200V
L1, L2, L3
Magnetic contactor
Single-Phase
24V
DC
CN2
U, V, W
Servomotor with Brake
200V
Brake power supply
SGDH
servo
amplifier
Brake control relay
M
PG
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......