Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 51
Manually Adjusting the Motor Current Detection Offset
Follow the procedure below to manually adjust the current detection offset.
Using the Hand-held Digital Operator
1.
Press the
DSPL/SET
key to select the auxiliary function mode.
2.
Select the parameter Fn00F.
Press the
Left Arrow
or
Right Arrow
key to select the digit.
Press the
Up Arrow
or
Down Arrow
key to change the value.
3.
Press the
DATA/ENTER
key, and the display will be as shown below.
4.
Press the
DSPL/SET
key to switch between the U-phase (Cu1_0) and V-phase
(Cu2_0) current detection offset adjustment mode
5.
Press the
Left Arrow
or
Right Arrow
key to display the current detection
data. Pressing the
Left Arrow
or
Right Arrow
key again will return to the
display shown above in step 3 or 4.
6.
Press the
Up Arrow
or
Down Arrow
key to adjust the offset. Carefully
adjust the offset while monitoring the torque reference monitor signal.
•
When making manual adjustments, run the motor at a speed of approximately 100rpm, and adjust
the Motor Current Detection Offset until the torque ripple, observed with the analog monitor, is
minimized.
(Refer to
Section 6.5 Analog Monitor.)
Adjust the U-phase and V-phase offsets alternately several times until these offsets are well balanced
.
IMPORTANT
DSPL/SET Key
Displayed
Alternately
Data Display
Left Cursor Key
(Right Cursor Key)
Displayed
Alternately
Data Setting Change
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......