Sigma II User’s Manual
Chapter 9: Inspection, Maintenance, and Troubleshooting
9 - 32
A.d0
A.d0: Position Error Pulse Overflow
Display and Outputs
Note:
OFF:
Output transistor is OFF (alarm state).
ON:
Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Output
ALM Output
ALO1
ALO2
ALO3
ON
ON
OFF
OFF
Cause of the Problem
Solution
A
Servomotor wiring incorrect or
poor connection
Check wiring and connectors at
encoder.
B
Servo amplifier was not correctly
adjusted.
Increase speed loop gain (Pn100)
and position loop gain (Pn102).
C
Motor load was excessive.
Reduce load torque or inertia. If
problem persists, replace with a
larger capacity motor.
D
Position reference pulse fre-
quency was too high.
•Increase or decrease reference
pulse frequency.
•Add smoothing function.
•Correct electronic gear ratio.
E
Circuit board (1PWB) defective.
Replace servo amplifier.
E
A
During servomotor operation.
During high speed
When a long reference
rotation
.
is entered during
normal operation.
When a properly entered
reference pulse does not
generate a feedback pulse.
At power ON.
A
B, C, D
E
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......