4.3 The Drive and Programming Modes
YASKAWA EUROPE SIEP
YASKAWA AC Drive L1000V Technical Manual
71
S
ta
rt
-U
p Pr
og
ra
mmin
g
&
O
p
er
at
io
n
4
n
Drive Mode Details
The following actions are possible in the Drive Mode:
• Run and stop the drive
• Monitor the operation status of the drive (speed reference, output speed, output current, output voltage, etc.)
• View information on an alarm
• View a history of alarms that have occurred
illustrates how to change the speed reference from 0.00% to 10.00% while in the Drive Mode. This example
assumes the reference source is assigned to the digital operator (b1-02 = 0) and d1-01 is set to 0 or 3.
Drive Mode
Output Frequency
Displays the drive output frequency.
Output Current
Displays the drive output current.
Output Voltage
Displays the drive output voltage. This monitor can be changed with the o1-01 parameter.
Monitor Display
Monitor menu with access to all drive monitors (U parameter group). Refer to U: Monitors on page 243 for more
details.
Programming
Mode
Verify Function
Lists all parameters that have been edited or modified from their default settings. Refer to Verifying Parameter
Changes: Verify Menu on page 73 for more details.
Setup Parameters
Lists commonly used parameters for quick drive commissioning. Refer to Simplified Setup Using the Setup Group
on page 74 for more details.
Parameter Setting
Allows the user to access and edit all paramter settings. Refer to Parameter Details on page 101 for more details.
Auto-Tuning
Procedure that calculates and sets the motor parameters automatically. Refer to Auto-Tuning on page 80 for more
details.
Drive Mode
Frequency Reference
Returns to the frequency reference display screen.
Mode
Contents
Operator Display
Description
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...