5.7 H: Terminal Functions
YASKAWA EUROPE
SIEP
YASKAWA AC Drive L1000V Technical Manual
129
5
Figure 5.15
Figure 5.15 Speed Detection 1 Time Chart
Refer to
L4-01, L4-02: Speed Agreement Detection Level and Detection Width on page 140
Setting 5: Speed Detection 2
Output closes whenever the output speed or motor speed is above the detection level set in L4-01. The terminal remains
closed until the output speed or motor speed falls below L4-01 minus the setting of L4-02.
Note:
Detection works in both forward and reverse. The value of L4-01 is used as the detection level for both directions.
Figure 5.16
Figure 5.16 Speed Detection 2 Time Chart
Refer to
L4-01, L4-02: Speed Agreement Detection Level and Detection Width on page 140
Setting 6: Drive ready
Output closes whenever the drive is ready to operate the motor. The terminal will not close under the conditions listed
below, and any Up/Down commands will be disregarded.
• When the power is shut off
• During a fault
• When the internal power supply of the drive has malfunctioned
• When a parameter setting error makes it impossible to run
• Although stopped, an overvoltage or undervoltage situation occurs
• While editing a parameter in the Programming Mode (when b1-08 = 0)
• When parameter L8-88 = 0 and at least one Safe Disable input is open
Setting 7: DC bus undervoltage
Output closes whenever the DC bus voltage or control circuit power supply drops below the trip level set in L2-05. A
fault in the DC bus circuit will also cause the terminal to set for “DC bus undervoltage” to close.
Status
Description
Open
Output speed or motor speed is below L4-01 minus L4-02 or has not exceeded L4-01.
Closed
Output speed or motor speed exceeded L4-01.
Status
Description
Open
DC bus voltage is above the level set to L2-05
Closed
DC bus voltage has fallen below the trip level set to L2-05.
L4-02
Speed
detection 1
ON
OFF
L4-02
L4-01
L4-01
Output speed
or motor speed
common̲
TMonly
L4-02
Speed
Detection 2
ON
OFF
L4-02
L4-01
L4-01
Output Speed
or motor speed
common̲
TMonly
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...