150
YASKAWA EUROPE SIEP
YASKAWA AC Drive L1000V Technical Manual
5.10 o: Operator Related Settings
5.10 o: Operator Related Settings
These parameters control the various functions, features, and display of the digital operator.
u
o1: Digital Operator Display Selection
These parameters determine the data display on the digital operator.
n
o1-01: Drive Mode Unit Monitor Selection
When the drive is powered up, the monitor selected in parameter o1-02 appears first on the display. If o1-02 is set to 5,
o1-01 can be used to change the content of this monitor.
When using an LED operator, pressing the up arrow key will display the following data: speed reference
→
rotational
direction
→
output speed
→
output current
→
o1-01 selection.
Parameter o1-01 selects the content of the last monitor in this sequence. There is no effect like this on an LCD operator.
n
o1-02: User Monitor Selection after Power Up
Selects which monitor parameter is displayed upon power up. This is done by entering the 1
part of U1-
. Certain
monitors are not available in some control modes.
Refer to U: Monitor Parameters on page 161
for a list of monitors.
Setting 1: Speed reference (U1-01)
Setting 2: Motor direction
Setting 3: Output speed (U1-02)
Setting 4: Output current (U1-03)
Setting 5: User-selected monitor (set by o1-01)
n
o1-03: Digital Operator Display Unit Selection
Sets the units used to display speed related settings and monitors as well as accel/decel rate settings and jerk settings.
Refer to
Digital LCD Operator Display Unit Selection on page 78
.
Setting 0: 0.01 Hz units
Setting 1: 0.01% units (100% = max. output frequency)
Setting 2: r/min units (calculated by the max output frequency and the no. of motor poles)
Setting 3: User-set units (use o1-10, o1-11)
Set o1-03 to 3 for user-set units, then set parameters o1-10 and o1-11.
Set the value use for the maximum frequency reference to o1-10. The placement of the decimal point in this number
should be set to o1-11.
For example, to have the maximum output speed displayed as “100.00”, set the o1-10 = 1000 and o1-11 = 2 (i.e., 1000
with 2 decimal points).
No.
<1> U2-
and U3-
parameters cannot be selected.
Name
Setting Range
Default
o1-01
Drive Mode Unit Monitor Selection
105 to 699
U1-04 (Control Mode) to
U6-99 (Option Monitor 20)
106 (U1-06)
No.
Name
Setting Range
Default
o1-02
User Monitor Selection after Power Up
1 to 5
1
No.
Name
Setting Range
Default
o1-03
Digital Operator Display Unit Selection
0 to 3
0
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...