6.7 Copy Function Related Displays
YASKAWA EUROPE SIEP
YASKAWA AC Drive L1000V Technical Manual
185
Tr
ouble
s
ho
ot
in
g
6
6.7
Copy Function Related Displays
u
Tasks, Errors, and Troubleshooting
The table below lists the messages and errors that may appear when using the Copy function.
When executing the tasks offered by the Copy function, the operator will indicate the task being performed. When an
error occurs, a code appears on the operator to indicate the error. Note that errors related to the Copy function do not
trigger a multi-function output terminal that has been set up to close when a fault or alarm occurs. To clear an error,
simply press any key on the operator and the error display will disappear.
lists the corrective action that can be taken when an error occurs.
Note: 1.
Whenever using the copy function, the drive should be fully stopped.
2.
The drive will not accept an Up/Down command while the Copy function is being executed.
3.
Parameters can only be saved to a drive when the voltage class, capacity, control mode, and software version match.
Table 6.11 Copy Function Task and Error Displays
Digital Operator Display
Task
CoPy
Writing Parameter Settings (flashing)
Cause
Possible Solutions
Parameters are being written to the drive.
Not an error.
Digital Operator Display
Task
CPEr
Control Mode Mismatch
Cause
Possible Solutions
Control mode of the parameters to be loaded onto the drive
and the control mode already set to the drive don’t match.
Check the control mode for the parameters that are to be loaded onto the drive and the control mode set to the drive
those parameters will be written to. Set the same control mode using parameter A1-02 and try again.
Digital Operator Display
Task
CPyE
Error Writing Data
Cause
Possible Solutions
Failed writing parameters.
Try writing parameters again.
Digital Operator Display
Task
CSEr
Copy Unit Error
Cause
Possible Solutions
Hardware fault
Replace the operator or the USB Copy Unit.
Digital Operator Display
Task
dFPS
Drive Model Mismatch
Cause
Possible Solutions
• The drives used in the copy and write process are not the
same model.
• The drive from which the parameters were copied is a
different model.
• The drive to be written to is a different model.
Check the model number of the drive from which the parameters were copied and the model of the drive to which you
are attempting to write the parameters. Make sure the two drives are the same model and have the same software
version.
Digital Operator Display
Task
End
Task Complete
Cause
Possible Solutions
Finished reading, writing, or verifying parameters.
Not an error.
Digital Operator Display
Task
iFEr
Communication Error
Cause
Possible Solutions
A communication error occurred between the drive and the
operator or the USB copy unit.
Check the cable connection.
A non-compatible cable is being used to connect the USB
Copy Unit and the drive.
Use the cable originally packaged with the USB Copy Unit.
Digital Operator Display
Task
ndAT
Model, Voltage Class, Capacity Mismatch
Cause
Possible Solutions
The drive from which the parameters were copied and the
drive to which you are attempting to write have different
electrical specifications, capacities, are set to different
control modes, or are different models.
Make sure model numbers and specifications are the same for both drives.
The device being used to write the parameters is blank and
does not have any parameters saved on it.
Making sure all connections are correct, and copy the parameter settings onto the USB Copy Unit or the operator.
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...