4.2 Using the Digital Operator
4.2
Using the Digital Operator
Use the digital operator to enter Run and Stop commands, edit parameters, and display data including fault and alarm
information.
♦ Keys and Displays
10
12
| ^Ф™¥*та
4
5 6
7
F ig u r e 4.1 K e y s a n d D is p la y s o n t h e D igital O p e r a to r
1
2
8
3
No.
Display
Name
Function
1
■
| l
Function Key
(F1, F2)
The functions assigned to F1 and F2 vary depending on the currently displayed menu. The name o f each
function appears in the lower h a lf o f the display window.
2
ESC Key
• Returns to the previous display.
• M oves the cursor one space to the left.
• Pressing and holding this button w ill return to the Speed Reference display.
3
RESET Key
• M oves the cursor to the right.
• R esets the drive to clear a fault situation.
4
^
^
r u n
|
R U N Key
Starts the drive in the LOCAL mode.
The Run LED
• is on, when the drive is operating the motor.
• flashes during deceleration to stop or when the speed reference is 0.
• flashes quickly, the drive is disabled by a DI, the drive was stopped using an emergency stop DI, or an Up/
D ow n command was active during power up.
5
□
Up Arrow Key
Scrolls up to display the next item, select parameter numbers, and increment setting values.
6
□
D ow n Arrow Key
Scrolls down to display the previous item, select parameter numbers, and decrements setting values.
7
STOP Key <1>
Stops drive operation.
8
[
enter
[
ENTER Key
• Enters parameter values and settings.
• Selects a menu item to m ove between displays.
9
i "
l
LO/RE Selection Key <2>
Switches drive control between the operator (LOCAL) and the control circuit terminals (REMOTE) for the
Run command and speed reference. The LED is on when the drive is in the LOCAL m ode (operation from
keypad).
10
ч t
^
k u n
|
R U N Light
Lit w hile the drive is operating the motor. Refer to page 80 for details.
11
Ц
Щ
LO/RE Light
L it w hile the operator is selected to run the drive (LOCAL mode). Refer to page 8 0 for details.
12
ALM
AL M LED Light
R efe r to A L A R M (ALM ) L E D D isp la ys on p a g e 79.
<1> The STOP key has highest priority. Pressing the STOP key will always cause the drive to stop the motor, even if an U p/D own command is
active at any external U p/D ow n comm and source. To disable the STOP key priority, set param eter o2-02 to 0.
<2> The LO/RE key can only switch between LOCAL and REM O TE when the drive is stopped. By default settings the LO/RE key function is
disabled. To allow using the LO /RE key for switching between LOCAL and REM OTE, set param eter o2-01 to 1.
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
77
St
art
-U
p
P
ro
g
ra
m
m
in
g
&
O
p
e
ra
ti
o
n
Содержание L1000A Series
Страница 68: ...3 11 Wiring Checklist 72 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 264: ...6 8 Diagnosing and Resetting Faults 268 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 308: ...8 5 Installing Peripheral Devices 312 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 316: ...A 5 Drive Derating Data 320 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 390: ...C 12 Self Diagnostics 394 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...