B.3 Parameter Table
♦ H: Multi-Function Terminals
H parameters assign functions to the multi-function input and output terminals.
■ H1: Multi-Function Digital Inputs
No.(Addr.)
Name
Description
Setting
Page
H1-03
(400H)
Terminal S3 Function Selection
A ssigns a function to the multi-function digital inputs.
Refer to page 3 3 6
to page 3 3 7
for a description o f setting values.
N o t e :
Unused terminals should be set to F.
Default: <19>
Min: 3
Max: 79
171
H 1-04
(401H)
Terminal S4 Function Selection
Default: <19>
Min: 3
Max: 79
171
H1-05
(402H)
Terminal S5 Function Selection
Default: <19>
Min: 3
Max: 79
171
H1-06
(403H)
Terminal S6 Function Selection
Default: <19>
Min: 3
Max: 79
171
H 1-07
(404H)
Terminal S7 Function Selection
Default: <19>
Min: 3
Max: 79
171
H1-08
(405H)
Terminal S8 Function Selection
Default: F
Min: 3
Max: 79
171
<19> W ith the speed reference priority d1-18 is set to 0 or 3, the default settings for parameters H1-03 to H 1-07 governing input term inals S3 to S7
are: 24, 14, 3, 4, and 5 respectively. W hen d1-18 is set to 1 or 2, the default settings for H1-03 to H 1-07 become 50, 54, 51, 53, and F
respectively.
H1 Multi-Function Digital Input Settings
H 1-D D
Setting
Function
3
Multi-Step Speed Reference 1
4
Multi-Step Speed Reference 2
5
Multi-Step Speed Reference 3
6
Jog reference selection
7
A ccel/decel Ramp Selection 1
8
Baseblock Command (N.O.)
9
Baseblock Command (N.C.)
F
N ot U sed (Through M ode)
14
Fault Reset
15
Emergency Stop (N .O .)
16
Motor 2 Selection
17
Emergency Stop (N .C.)
18
Timer Function Input
1A
A ccel/decel Ramp Selection 2
Description
Page
W hen input terminals are set to Multi-Step Speed References 1 through 3, switching combinations o f those
terminals w ill create a multi-step speed sequence using the speed references set in d1-01 through d1-08.
171
Closed: Jog frequency reference (d1-17) selected.
The Jog frequency can be used when the speed reference selection is not assigned to input terminals (b1-01 Ф 1)
and the speed reference priority is set to use the multi-step speed reference (d1-18 = 0 or 3).
171
U sed to switch between accel/decel ramp 1 (set in C 1-01, C 1-02) and accel/decel ramp 2 (set in C1-03, C1-04).
W hen combined with another input terminal set for "Accel/Decel ramp 2" (H 1 -D D = 1A), the drive can also
switch between accel/decel ramp 3 (set in C1-05, C 1-06) and accel/decel ramp 4 (set in C1-07, C1-08).
Closed: N o drive output
172
Open: N o drive output
Select this setting when using the terminal in a pass-through mode. The terminal does not trigger a drive function
but can be used as digital input for the controller the drive is connected to.
172
Closed: R esets faults i f the cause is cleared and the U p/Dow n command is removed.
172
Closed: Decelerates to stop at the Emergency Stop ramp set to C1-09.
Open: Motor 1(Е 1-П П , Е 3 -П П )
Closed: Motor 2 (Е 2 -П П , Е 4 -П П )
173
Open: Decelerates to stop at the Emergency Stop ramp set to C1-09.
172
Triggers the timer set up by parameters b4-01 and b4-02. Must be set in conjunction with the timer function output
(H 2 -D D = 12).
U sed in conjunction with an input terminal set for “A ccel/decel ramp selection 1” (H 1 -D D = 7), and allows the
drive to switch between accel/decel ramp 3 and 4.
171
171
171
172
172
173
173
336
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
Содержание L1000A Series
Страница 68: ...3 11 Wiring Checklist 72 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 264: ...6 8 Diagnosing and Resetting Faults 268 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 308: ...8 5 Installing Peripheral Devices 312 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 316: ...A 5 Drive Derating Data 320 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 390: ...C 12 Self Diagnostics 394 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...