B.3 Parameter Table
■ b1: Operation Mode Selection
No.(Addr.)
Name
Description
Setting
Page
b1-01
(180H)
Speed Reference Selection
D igital operator
Analog input terminals
M EM OBUS/M odbus communications
Option card
Default: 0
Min: 0
Max: 3
139
b1-02
(181H)
U p/Dow n Command Selection
D igital operator
D igital input terminals
M EM OBUS/M odbus communications
Option card
Default: 1
Min: 0
Max: 3
b1-03
(182H)
Stopping Method Selection
0: Ramp to stop
1: Coast to stop
Default: 0
Min: 0
Max: 1
140
b1-06
(185H)
D igital Input Reading
0: Input status is read once and processed immediately (for quick response)
1: Input is read tw ice and processed only if the status is the same in both readings (robust
against noisy signals)
Default: 1
Min: 0
Max: 1
b1-08
(187H)
U p/Dow n Command Selection
w hile in Programming Mode
U p/D ow n command not accepted w hile in the Programming Mode.
U p/D ow n command accepted w hile in the Programming Mode.
Prohibit entering Programming M ode during run.
Default: 1
Min: 0
Max: 2
b1-14
(1C3H)
Phase Order Selection
0: U-V-W
1: U-W -V
Default: 0
Min: 0
Max: 1
141
140
140
141
■ b2: Magnetic Flux Compensation
No.(Addr.)
Name
Description
Setting
Page
b2-08
(190H)
Magnetic Flux Compensation
Value
Г " ™
Sets the magnetic flux compensation as a percentage o f the no-load current value (E2-03).
Default: 0%
Min: 0%
Max: 1000%
141
■ b4: Delay Timers
No.(Addr.)
Name
b4-01
(1A3H)
Timer Function On-Delay Time
b4-02
(1A4H)
Timer Function Off-Delay Time
Description
U sed to set the on-delay and off-delay times for a digital timer output (H 2 -D D = 1 2). The output
is triggered by a digital input programmed to H 1 -D D = 1 8 )
Setting
Page
Default: 0.0 s
Min: 0.0 s
Max: 3000.0 s
142
Default: 0.0 s
Min: 0.0 s
Max: 3000.0 s
142
■ b6: Dwell Function
No.(Addr.)
Name
|
Description
Setting
Page
b6-01
(1B6H)
D w ell Speed at Start
Default: 0.0%
Min: 0.0%
Max: 100.0%
142
b6-02
(1B7H)
D w ell Time at Start
Default: 0.0 s
Min: 0.0 s
Max: 10.0 s
142
b6-03
(1B8H)
D w ell Speed at Stop
Parameters b6-01 and b6-02 set the speed to hold and the tim e to maintain that speed at start.
Parameters b6-03 and b6-04 set the speed to hold and the tim e to maintain that speed at stop.
Default: 0.0%
Min: 0.0%
Max: 100.0%
142
b 6-04
(1B9H)
D w ell Time at Stop
Default: 0.0 s
Min: 0.0 s
Max: 10.0 s
142
■ b7: Droop Control
No.(Addr.)
b7-01
(1CAH)
Name
Description
Droop Control Gain
Sets the speed reduction gain applied at a torque reference o f 100%. Set as a percentage of
motor base speed.
Setting
Page
Default: 0.0%
Min: 0.0%
Max: 100.0%
143
Default: 0.05 s
Min: 0.03 s
Max: 2.00 s
143
b7-02
(1CBH)
Droop Control D elay Time
U sed to adjust the responsiveness o f Droop Control.
V/f
CLV
CLV/PM
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
325
P
a
ra
m
e
te
r
L
is
t
Содержание L1000A Series
Страница 68: ...3 11 Wiring Checklist 72 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 264: ...6 8 Diagnosing and Resetting Faults 268 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 308: ...8 5 Installing Peripheral Devices 312 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 316: ...A 5 Drive Derating Data 320 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 390: ...C 12 Self Diagnostics 394 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...