B.5 Defaults by Drive Model Selection (o2-04)
B.5 Defaults by Drive Model Selection (o2-04)
The following tables show parameters and default settings that change with the drive model selection (o2-04). Parameter
numbers shown in parenthesis are valid for motor 2.
Table B.4 200 V Class Drives Default Settings by Drive Model Selection
No.
Name
Unit
Default Settings
-
Model CIMR-LC
-
2A0018
2A0025
2A0033
2A0047
2A0060
2A0075
2A0085
o2-04
Drive Model Selection
Hex.
68
6A
6B
6D
6E
6F
70
E2-11
Motor Rated Output
kW
4.0
5.5
7.5
11
15
18.5
22
C5-17
(C 5-37)
Motor Inertia
kgm 2
0.0158
0.026
0.037
0.053
0.076
0.138
0.165
C6-03
Carrier Frequency
kHz
8
8
8
8
8
8
8
E2-01
(E4-01)
Motor Rated Current
A
14
19.6
26.6
39.7
53
65.8
77.2
E2-02
(E4-02)
Motor Rated Slip
Hz
2.73
1.5
1.3
1.7
1.6
1.67
1.7
E2-03
(E4-03)
Motor No-Load Current
A
4.5
5.1
8
11.2
15.2
15.7
18.5
E2-05
(E4-05)
Motor Line-to-Line Resistance
n
0.771
0.399
0.288
0.23
0.138
0.101
0.079
E2-06
(E4-06)
Motor Leakage Inductance
%
19.6
18.2
15.5
19.5
17.2
20.1
19.5
E2-10
(E4-10)
Motor Iron L oss for Torque Compensation
W
112
172
262
245
272
505
538
E3-08
Motor 2 M id Output Frequency Voltage
V
18.6
18.6
18.6
18.6
18.6
18.6
18.6
E3-10
Motor 2 Minimum Output Frequency Voltage
V
9.7
9.7
9.7
9.7
9.7
9.7
9.7
E5-02
Motor Rated Power
kW
4.0
5.5
7.5
11
15
18.5
22
E5-03
Motor Rated Current
A
14.6
20
29.3
37.9
53.2
65
76.4
E5-05
Motor Stator Resistance
n
0.331
0.37
0.223
0.153
0.095
0.069
0.054
E5-06
Motor d-Axis Inductance
mH
4.78
5.39
3.58
3.46
2.46
1.99
1.7
E 5-07
Motor q-Axis Inductance
mH
6.52
7.36
4.89
4.96
3.7
2.99
2.55
E5-09
Motor Induction Voltage Constant 1
mV/(rad/sec)
239.3
254.3
237
270
254.3
256.7
261.1
L8-02
Overheat Alarm Level
°C
110
120
125
120
120
125
130
L8-06
Input Phase Loss Detection Level
%
14.0
18.0
20.0
22.0
20.0
21.0
21.0
L8-35
Installation Method Selection
-
2
2
2
2
2
2
2
n5-02
Motor Acceleration Time
s
0.154
0.168
0.175
0.265
0.244
0.317
0.355
n9-60
A /D Conversion Start Delay
^sec
14.0
14.0
14.0
14.0
14.0
14.0
14.0
No.
Name
Unit
Default Settings
-
Model CIMR-LC
-
2A0115
2A0145
2A0180
2A0215
2A0283
2A0346
2A0415
o2-04
Drive Model Selection
Hex.
72
73
74
75
76
77
78
E2-11
Motor Rated Output
kW
30
37
45
55
75
90
110
C5-17
(C 5-37)
Motor Inertia
kgm2
0.220
0.273
0.333
0.49
0.90
1.10
1.90
C6-03
Carrier Frequency
kHz
8
5
5
5
5
2
2
E2-01
(E4-01)
Motor Rated Current
A
105
131
160
190
260
260
260
E2-02
(E4-02)
Motor Rated Slip
Hz
1.8
1.33
1.6
1.43
1.39
1.39
1.39
E2-03
(E4-03)
Motor No-Load Current
A
21.9
38.2
44
45.6
72
72
72
E2-05
(E4-05)
Motor Line-to-Line Resistance
n
0.064
0.039
0.03
0.022
0.023
0.023
0.023
E2-06
(E4-06)
Motor Leakage Inductance
%
20.8
18.8
20.2
20.5
20
20
20
E2-10
(E4-10)
Motor Iron Loss for Torque Compensation
W
699
823
852
960
1200
1200
1200
E3-08
Motor 2 M id Output Frequency Voltage
V
18.6
18.6
18.6
16.0
16.0
16.0
16.0
E3-10
Motor 2 Minimum Output Frequency Voltage
V
9.7
9.7
9.7
8.3
8.3
8.3
8.3
E5-02
Motor Rated Power
kW
30
37
45
55
75
90
110
E5-03
Motor Rated Current
A
103.5
133.1
149.4
181.6
181.6
181.6
181.6
E5-05
Motor Stator Resistance
n
0.041
0.027
0.022
0.016
0.016
0.016
0.016
E5-06
Motor d-Axis Inductance
mH
1.29
0.91
0.9
0.72
0.72
0.72
0.72
E 5-07
Motor q-Axis Inductance
mH
2
1.41
1.39
1.11
1.11
1.11
1.11
E5-09
Motor Induction Voltage Constant 1
m V/(rad/sec)
260.4
245.1
276
0.317
0.533
0.592
0.646
L 8-02
Overheat Alarm Level
°C
130
130
125
115
120
120
120
L8-06
Input Phase Loss Detection Level
%
17.0
27.0
28.0
17
16
24
22
L8-35
Installation Method Selection
-
0
0
0
0
0
0
0
n5-02
Motor Acceleration Time
s
0.323
0.32
0.387
0.317
0.533
0.592
0.646
n9-60
A /D Conversion Start Delay
^sec
14.0
14.0
14.0
14.0
14.0
14.0
14.0
I E
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
363
P
a
ra
m
e
te
r
L
is
t
Содержание L1000A Series
Страница 68: ...3 11 Wiring Checklist 72 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 264: ...6 8 Diagnosing and Resetting Faults 268 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 308: ...8 5 Installing Peripheral Devices 312 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 316: ...A 5 Drive Derating Data 320 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 390: ...C 12 Self Diagnostics 394 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...