![YASKAWA JUSP-NS115 Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076091.webp)
4.3 Main Commands
4-47
4
Sub-control: SUBCTRL
Select Latch Signal: L_SGN
Select Motion: MOTION
Sequence Signals: SQ_CMD
D7
D6
D5
D4
D3
D2
D1
D0
RESERVE
0
MOTION
Select motion
RESERVE
0
SET_L
Latch
command
L_SGN
Select latch signal
D1
D0
Latch Signal
0
0
Phase C
0
1
EXT1
1
0
EXT2
1
1
EXT3
D6
D5
D4
Motion
• During phase 1, a parameter setting
warning (A.94) will occur for POSING
and FEED, and the commands will be
ignored.
• For INTERPOLATE, in all other phases
except phase 3, a parameter setting
warning (A.94) will occur and the com-
mand will be ignored.
• A warning may not be given depending
on the sequence signal status.
0
0
0
HOLD
0
0
1
INTERPOLATE
0
1
0
FEED
0
1
1
POSING
D7
D6
D5
D4
D3
D2
D1
D0
RESERVE
0
ACLR
Alarm
clear
SEN
Sensor ON
BRK
Brake ON
SON