![YASKAWA JUSP-NS115 Скачать руководство пользователя страница 188](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076188.webp)
9.1 Alarm Displays and Troubleshooting
9-13
9
A.CC
A.CC: Multiturn Limit Disagreement Alarm
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state). ON: Output transistor is
ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
ON
OFF
ON
OFF
Cause
Remedy
A
The setting of the Multiturn Limit Setting
(Pn205) parameter in the SERVOPACK is
incorrect.
Change parameter Pn205.
B
The multiturn limit has not been set in the
encoder.
Check to be sure the Multiturn Limit Set-
ting (Pn205) parameter in the SERVO-
PACK is correct, and then execute the
encoder multiturn limit setting change
(Fn013) when a Multiturn Limit Disagree-
ment Alarm (A.CC) occurs.
At power ON
A, B