Table 9.2 Alarm Displays and Outputs
Alarm
Display
Alarm Code Outputs
ALM
Output
Alarm Name
Description
ALO1
ALO2
ALO3
A.02
OFF
OFF
OFF
OFF
Parameter Breakdown
∗
2
EEPROM data of SERVOPACK is incorrect.
A.03
Main Circuit Detector or
Sensor Error
Faulty power circuit sensor.
A.04
Parameter Setting Error
∗
2
The parameter setting is outside the allowable
setting range.
A.05
∗
4
Combination Error
SERVOPACK and servomotor capacities do no
match each other.
A.10
∗
4
ON
OFF
OFF
OFF
Overcurrent or Heat Sink
Overheated
∗
2
An overcurrent flowed through the IGBT.
Heat sink of SERVOPACK was overheated.
A.30
∗
4
ON
ON
OFF
OFF
Regeneration Error
• Regenerative circuit is faulty.
• Regenerative resistor is faulty.
A.32
∗
4
Regenerative Overload
Regenerative energy exceeds regenerative
resistor capacity.
A.40
∗
4
OFF
OFF
ON
OFF
Overvoltage
∗
3
Main circuit DC voltage is excessively high.
A.41
∗
4
Undervoltage
∗
3
Main circuit DC voltage is excessively low.
A.51
∗
4
ON
OFF
ON
OFF
Overspeed
Rotational speed of the motor is excessively
high.
A.71
∗
4
ON
ON
ON
OFF
Overload: High Load
The motor was operating for several seconds to
several tens of seconds under a torque largely
exceeding ratings.
A.72
∗
4
Overload: Low Load
The motor was operating continuously under a
torque largely exceeding ratings.
A.73
∗
4
Dynamic Brake Overload
When the dynamic brake was applied, rota-
tional energy exceeded the capacity of dynamic
brake resistor.
A.74
∗
4
Overload of Surge Current
Limit Resistor
The main circuit power was frequently turned
ON and OFF.
A.7A
∗
4
Heat Sink Overheated
∗
1