4 MECHATROLINK-
II
Communications
4.3.17 Turn Sensor OFF (SENS_OFF: 24H)
4-24
4.3.17
Turn Sensor OFF (SENS_OFF: 24H)
Byte
SENS_OFF
Description
Command
Response
1
24H
24H
Processing
classifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within 500 ms
Subcommand
Cannot be used.
3
STATUS
• Turns sensor OFF. The position data is not specified.
• The reference point, zero point (ZPOINT), and software limits will be enabled.
• Can be used during phases 2 and 3.
• If an incremental encoder is being used, the command will be ignored.
• During phase 1, a MECHATROLINK-II command warning (A.95) will occur
and the command will be ignored.
4
5
MONITOR 1
6
7
8
9
MONITOR 2
10
11
12
13
SEL_MON 1/2
SEL_MON 1/2
14
IO_MON
15
16
WDT
RWDT