Appendix B List of Parameters
B-8
* Parameter changing method is as follows:
: Can be changed at any time, and immediately enabled after changing. (Called an online
parameter.)
{
: Can be changed when DEN = 1. Immediately enabled after changing. Do not change
when DEN = 0. Doing so may lead to misoperation, such as position errors. (Called an
online parameter.)
∆
: Can be changed at any time, and enabled immediately after the power is turned OFF then
ON again. Sends a Set Up Device command at power-ON when changing a parameter.
(Called an offline parameter.)
−
: Do not access.
Supplementary
Commands
Pn814
Pn815
Final Travel Distance for External
Positioning
4
reference unit
-2
30
+1 to
2
30
-1
100
{
Pn816
Zero Point Return Mode Setting
2
−
0000H to
0001H
0000H
{
Pn817
Zero Point Return Approach Speed
1
2
100 reference
unit/s
0 to 65535
50
{
Pn818
Zero Point Return Approach Speed
2
2
100 reference
unit/s
0 to 65535
5
{
Pn819
Pn81A
Final Travel Distance to Return to
Zero Point
4
reference unit
-2
30
+1 to
2
30
-1
100
{
Pn81B
Backlash Compensation Amount
2
0.1 reference
unit
-32768 to
32767
0000H
Pn81C
Reserved by system
2
−
−
0000H
−
Pn81D
Compensation Function Selection
2
−
0000H to
0001H
0000H
∆
Monitor
Pn81E
Input Signal Monitor Selection
2
−
0000H to
7777H
0000H
Pn81F
Reserved by system
2
−
−
0000H
−
Supplementary
Commands
Pn820
Pn821
Latching Area Upper Limit
4
reference unit
-2
31
to
2
31
-1
00000000H
Pn822
Pn823
Latching Area Lower Limit
4
reference unit
-2
31
to
2
31
-1
00000000H
Table B.2 NS115 Parameter List (cont’d)
Category
Pn No.
Name
Size
Unit
Setting
Range
NS115
Factory
Setting
Changing
Method *