![YASKAWA JUSP-NS115 Скачать руководство пользователя страница 177](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076177.webp)
9 Troubleshooting
9-2
9.1
Alarm Displays and Troubleshooting
Problems that occur in the servodrives are displayed on the panel operator as “A.
” or
“CPF
”. “A.
− −
”, however, does not indicate an alarm. Refer to the following sections to
identify the cause of an alarm and the action to be taken.
Contact your Yaskawa representative if the problem cannot be solved by the described proce-
dures.
A.02
A.02: Parameter Breakdown
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
OFF
OFF
Cause
Remedy
A
Power turned OFF during parameter write.
Alarm occurred at next power ON.
• Initialize parameters using Fn005 and
reinput user settings.
• Replace the SERVOPACK.
B
Circuit board (1PWB) is defective.
Replace the SERVOPACK.
C
NS115 is defective.
Replace the NS115.
A, B, C
At power ON