![YASKAWA JUSP-NS115 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076057.webp)
4.3 Main Commands
4-13
4
4.3.6
Read Alarm or Warning (ALM_RD: 05H)
* Alarm occurrence history is saved on E
2
PROM, and will not be lost if
power goes OFF.
Details of ALM_RD_MOD
Byte
ALM_RD
Description
Command
Response
1
05H
05H
Processing clas-
sifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Refer to
Details of
ALM_RD_MOD.
Subcommand
Cannot be used
.
3
STATUS
• Reads the following alarm or warning status.
- Current alarm/warning status
- Alarm status history* (warning history is not preserved.)
• The ALM_RD_MOD specifications are shown in the following table.
• The latest error and warning information is contained from byte 6 onwards of
the ALM_DATA. When there are no errors or warnings, the remaining bytes
are normal (99H).
• A warning will occur and the command will be ignored in the following cases.
- If a digital operator is connected: MECHATROLINK-II command warning
(A.95)
- If SigmaWin and so on are connected: MECHATROLINK-II command
warning (A.95)
- If ALM_RD_MOD is not within range: Parameter setting warning (A.94)
4
5
ALM_RD_MOD ALM_RD_MOD
6
ALM_DATA
7
8
9
10
11
12
13
14
15
16
WDT
RWDT
ALM_RD_MOD
Description Processing
Time
0
Read current alarm/warning status
10 items max. (sixth to fifteenth byte)
Within commu-
nications cycle
1
Read alarm status history
10 items max. (sixth to fifteenth byte)
(Warning history is not preserved.)
Within 2 s