4.3 Main Commands
4-29
4
4.3.22
Servo ON (SV_ON: 31H)
Byte
SV_ON
Description
Command
Response
1
31H
31H
Processing
classifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within 50 ms nor-
mally
Subcommand
Can be used.
3
OPTION
STATUS
• The SERVOPACK changes to Servo ON.
• Can be used during phases 2 and 3.
• A MECHATROLINK-II command warning (A.95) will occur and the com-
mand will be ignored in the following cases.
- During phase 1
- During alarm occurrence (when ALM of STATUS is 1)
- If SENS_ON has not been completed when the absolute encoder is
used
• OPTION can be selected. Refer to
4.5.2 Option Field Specifications:
OPTION
for details.
• For linear motors not equipped with a pole sensor, it takes 10 seconds max.
until the SERVOPACK changes to Servo ON the first time because the pole
must be detected.
• Upon completion of this command, the reference position (POS) must be read,
and the controller coordinate system must be set up.
4
5
MONITOR1
6
7
8
9
MONITOR2
10
11
12
13
SEL_MON 1/2
SEL_MON 1/2
14
IO_MON
15
16
WDT
RWDT
17
For
subcommands
use. Refer to
4.4 Subcom-
mands
.
For
subcommands
use. Refer to
4.4 Subcom-
mands
.
18
19
20
21
22
23
24
25
26
27
28
29