![YASKAWA JUSP-NS115 Скачать руководство пользователя страница 184](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076184.webp)
9.1 Alarm Displays and Troubleshooting
9-9
9
A.94
A.94: Parameter Setting Warning
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state). ON: Output transistor is
ON.
Status and Remedy for Alarm
A.95
A.95: MECHATROLINK-II command warning
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state). ON: Output transistor is
ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
ON
ON
OFF
ON
Cause
Remedy
A
A value outside the MECHATROLINK-II
communications setting range was set.
Reset correctly.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
ON
ON
OFF
ON
Cause
Remedy
A
Presently unable to receive the sent command. Adjust conditions to match the command.
Refer to the specifications for each com-
mand.
B
Unsupported command.
Do not sent unsupported commands.
Occurred when the
command was sent
A
Occurred when the
command was sent
A, B