9 Troubleshooting
9-16
A.E2
A.E2: NS115 WDC Error
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state). ON: Output transistor is
ON.
Status and Remedy for Alarm
A.E4
A.E4: MECHATROLINK-II Transmission Cycle Setting Error
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state). ON: Output transistor is
ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
ON
ON
OFF
Cause
Remedy
A
NS115 is defective.
Replace the NS115.
B
MECHATROLINK-II communications inter-
rupted.
Turn the power ON again.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
ON
ON
OFF
Cause
Remedy
A
The setting of MECHATROLINK-II trans-
mission cycle is out of range.
Correct the setting of MECHATROLINK-
II transmission cycle.
At power ON
A
During MECHATROLINK-
II
communications
B
Occurred when a CONNECT
command was sent
A