![YASKAWA JUSP-NS115 Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/yaskawa/jusp-ns115/jusp-ns115_user-manual_907076069.webp)
4.3 Main Commands
4-25
4
4.3.18
Stop Motion (HOLD: 25H)
Related Parameters
Byte
HOLD
Description
Command
Response
1
25H
25H
Processing
classifications
Motion command
group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within communi-
cations cycle
Subcommand
Can be used.
3
OPTION
STATUS
• From current motion status, performs a deceleration stop and positioning
according to the deceleration value set in the parameters.
• Can be used during phases 2 and 3.
• During phase 1, a MECHATROLINK-II command warning (A.95) will occur
and the command will be ignored.
• OPTION can be selected. Refer to
4.5.2 Option Field Specifications: OPTION
for details.
• Use DEN (output complete) to confirm the completion of motion processing.
• Latch processing, which is dependent on LATCH, EX_POSING, and SVC-
TRL will be cancelled.
• ZRET latch processing and ZRET zero point alignment will be cancelled.
• Upon completion of this command, the reference position (POS) must be read,
and the controller coordinate system must be set up.
• The stop method can be selected using HOLD_MOD.
0: Decelerate to a stop according to the deceleration parameter.
1: Stop immediately (output stop).
4
5
HOLD_MOD
MONITOR1
6
7
8
9
MONITOR2
10
11
12
13
SEL_MON 1/2
SEL_MON 1/2
14
IO_MON
15
16
WDT
RWDT
17
For
subcommands
use. Refer to
4.4 Subcom-
mands
.
For
subcommands
use. Refer to
4.4 Subcom-
mands
.
18
19
20
21
22
23
24
25
26
27
28
29
Pn No.
Description
Pn80D
First-step Linear Deceleration Parameter
Pn80E
Second-step Linear Deceleration Parameter
Pn80F
Deceleration Parameter Switching Speed