![background image](http://html.mh-extra.com/html/yaskawa/japmc-mc2100/japmc-mc2100_user-manual_907066076.webp)
3.4 Self-configuration and Definition Files
3.4.4 Current Value and Setting Data in SVB
3-32
( 5 ) Copying Current Values to Set Values (Input Data) in the SERVOPACK Tab
The data flow for SERVOPACK parameters is as follows when selecting
Edit - Copy Current Value
from the SERVO-
PACK Tab in the SVB Definition Window on the MPE720:
• The MPE720 copies the values currently displayed in
Current
to
Input Data
on the SERVOPACK Tab and dis-
plays.
indicates data has been written.
The following figure shows a display example after having selected
Edit - Copy Current Value
on the SERVOPACK
Tab in the
SVB Definition
Window. The values in
Current
are copied to
Input Data
.
MECHATROLINK
RAM
EEP
-ROM
SRAM
SDRAM
Machine Controller
SERVOPACK
SERVOPACK
Control
Software
System
Software
Parameters
SERVOPACK Parameters
(All Axes)
Flash
Memory
Input
Data
MPE720
㧔
online
㧕
HDD in personal computer
Display
Current
Value
Input
Data
Before copying
After copying