1.2 Specifications
1.2.2 Specifications of SVB Module
1-10
For more information on the hardware specifications for the built-in SVB Module, refer to the manual for your
machine controller.
1.2.2 Specifications of SVB Module
This section describes the specifications of the built-in and the optional SVB modules are as follows.
( 1 ) Motion Control Function
* 1. Only for the SVB-01 Module.
Mass
80 g
(cont’d)
Item
Specifications
Item
Details
MECHA
T
ROLI
NK Communi
cat
io
n
Number of Communication
Lines
One line
Number of Communication
Ports (Connectors)
SVB-01, MP2100M, and MP2500M/MP2500MD
2 ports
MP2100, MP2300, MP2500, and MP2500D
1 port
Terminating Resistance
JEPMC-W6022 terminator must be purchased separately.
Transmission Distance
MECHATROLINK-II
Min. distance between stations: 0.5 m
Total network length: 50 m (can be extended to 100 m by connecting repeaters)
MECHATROLINK-I
Min. distance between stations: 0.3 m
Total network length: 50 m (can be extended to 100 m by connecting repeaters)
M
as
ter Fu
n
cti
on
s
Communication Interface
MECHATROLINK-II (2:N synchronous)
MECHATROLINK-I (1:N synchronous)
Baud Rate
10 Mbps
4 Mbps
Transmission Cycle
0.5 ms
*1
, 1 ms, 1.5 ms, or 2 ms
2 ms
Number of Link
Communication Bytes
17 bytes or 32 bytes
17 bytes
Number of Connectable
Stations
Up to 21 stations
(SERVOPACK for up to 16 axes)
Up to 14 stations
C1 Messaging
(Master Function)
Provided (selectable).
Not provided.
C2 Messaging
(Allocations)
Provided (selectable).
Not provided.
Retry Function
Provided (selectable).
Not provided.
Supported Slave Devices
For details, refer to
1.1.5 Devices Connectable to MECHATROLINK
.
Sl
ave
F
unct
io
n
s
*1
Communication Interface
MECHATROLINK-II
MECHATROLINK-I
Baud Rate
10 Mbps
4 Mbps
Transmission Cycle
The transmission cycle of the master station
(0.5 ms min.)
2 ms
Number of Link
Communication Bytes
17 bytes or 32 bytes
17 bytes
Messaging
(Slave Function)
Supported.
Not supported.