23
5. How to use the function menu (MODE key)
Contents of the menu
The function menu has the following functions. This section shows the indications of each function
called for and explains each of functions briefly. For how to set and input functions, see the sections
that explain those functions.
(Note
:
Model BF600 does not support indication of a temperature with a decimal point
)
Display after operation and operating procedures
Description
1
〈
Sub display switching function
〉
Example of the sub display switching mode
Press the
[MODE] key
Press the [MODE] key.
When pressed during operation
The indication changes to that of the sub
display switching mode.
*
See P.26
“To change the sub display
indication”.
When pressed during stand-by or at the end
of a program
The indication changes to that of the
preset temperature registration mode.
*
See P.31
“How to use the temperature
preset function”.
〈
Temperature preset function
〉
Example of the preset temperature
registration mode
2
〈
Panel key lock function
〉
Press the [
▼
]
or the [
▲
] key.
Press the [▼] or the [▲] key several times.
The mode changes to the panel key lock
select mode.
*
The panel key lock is a function to prevent
inadvertent changes of settings during
operation or stand-by. When this function
is [ON], any key operations other than the
[MODE] key are disabled.
*
See P.27
“Setting and cancelling the panel
key lock”.
〈
Accumulated time display function
〉
Display when accumulated time has
exceeded 10,000 hours
Pres
s the [▼] or the [▲] key several times.
The mode changes to the Accumulated
time display mode and the indication in the
main display changes to flashing
(
meaaning Accumulation
)
.
The indicattion in the sub display changes
to accumulated time display in the power
ON status.
*
Up to 4,999 hours can be indicated as
accumulated time in the unit of hours. (You
cannot reset the time)
*
When the time exceeds 9999 hours, each
time 10,000 hours are exceeded, dot at
each digit will come on as shown in the
example on the left (One dot means
10,000 hours.)
〈
Error beep ON/OFF function
〉
Press the [▼] or the [▲] key several times.
The mode changes to the error beep
ON/OFF select mode.
*
This function is used to enable or disable
the buzzer alarm function when an error
occurs to the unit.
*
See P.28
“Setting and cancelling the error
beep”.
Example: Present
accumulated time
Indication when
error beep is
enabled
Indication when
error beep is
disabled
Indication when
the panel key
lock is enabled
Indication when
the panel key
lock is disabled
or
10050 hours
20050 hours
30050 hours
40050 hours
or