Model selection table
The following shows the model selection table of this unit:
Basic
Mounting Control
PV
Power
Option 1
Option 2 Additional
Specifications
Remarks
model No.
output
input
supply
treatment
C35
SDC35 Mask size 48 mm X 96 mm
C36
SDC36 Mask size 96 mm X 96 mm
T
Panel mounting type
Control output 1
Control output 2
R0
Relay output NO
Relay output NC
(Note 3)
R1
Motor drive relay output
Motor drive relay output
With
OPEN side
CLOSE side
MFB
V0
Voltage pulse output
None
(for SSR drive)
VC
Voltage pulse output
Current output
(for SSR drive)
VD
Voltage pulse output
Continuous voltage output
(for SSR drive)
VV
Voltage pulse output
Voltage pulse output
(for SSR drive)
(for SSR drive)
C0
Current output
None
CC
Current output
Current output
CD
Current output
Continuous voltage output
D0
Continuous voltage output
None
DD
Continuous voltage output
Continuous voltage output
U
Universal
A
AC Model (100 to 240Vac)
D
DC Model (24Vac/24Vdc)
1
Event relay outputs 3 points
2
Event relay output: 3 points, auxiliary output (current output)
3
Event relay output: 3 points, auxiliary output (voltage output)
(Note 3)
4
Event relay output: 2 points (independent contact)
(Note 3)
5
Event relay output: 2 points (independent contact),
auxiliary output (current output)
(Note 3)
6
Event relay output: 2 points (independent contact),
auxiliary output (voltage output)
0
None
(Notes 1, 2)
1
Current transformer input: 2 points,
Digital input: 4 points
(Notes 1, 2)
2
Current transformer input: 2 points,
Digital input: 4 points, RS-485 communication
(Notes 1, 2)
3
Current transformer input: 2 points,
Digital input: 2 points, RSP input
(Notes 1, 2)
4
Current transformer input: 2 points,
Digital input: 2 points, RSP input, RS-485 communication
00
No additional treatment
D0
Inspection Certificate provided
T0
Tropicalization treatment applied
K0
Anti-sulfide treatment applied
B0
Tropicalization treatment applied and
Inspection Certificate provided
L0
Anti-sulfide treatment applied and
Inspection Certificate provided
Y0
Complying with the traceability certification
Note 1.
Current transformer sold separately.
Note 2.
When the control output is R1, the
current transformer input is not applied.
MFB input is applied instead.
Note 3.
Can not be selected for the DC Model.
Содержание SDC35
Страница 16: ......
Страница 17: ......
Страница 19: ... display key para key or V key key enter key 2 second press hold of para key V ...
Страница 32: ......
Страница 46: ......
Страница 58: ......
Страница 71: ......
Страница 78: ...5 20 Chapter 5 DETAILED DESCRIPTION OF EACH FUNCTION Item Bank Display Contents Initial value User level ...
Страница 84: ......
Страница 95: ......
Страница 172: ......
Страница 174: ...6 2 Chapter 6 LIST OF DISPLAYS AND SETTING DATA ...
Страница 211: ......
Страница 230: ......
Страница 240: ......
Страница 248: ......
Страница 260: ......
Страница 268: ......
Страница 270: ......
Страница 279: ......