4-
224
Operation
4
14. “UTILITY” mode
14.2 Enabling/disabling the sequence execution flag
To enable or disable execution of sequence programs, proceed as follows.
[Procedure]
1) Press the
F 2
(SEQUENC) key in “UTILITY” mode.
2) To enable execution of sequence programs, press the
F 1
(ENABLE) key.
To disable execution of sequence programs, press the
F 2
(DISABLE) key.
To enable DO reset during sequence program execution, press the
F 6
(RST.DO)
key.
Fig. 4-14-6 Enabling/disabling the sequence program
UTILITY
>SEQUENC
Scan time : 10msec
Sequence : ENABLE
ENABLE
DISABLE
n
NOTE
The following conditions must be
satisfied before executing a sequence
program.
1. An object program must be made
for sequence execution.
2. Sequence execution must be
enabled.
3. DI10 (Sequence control) contact
point must be closed.
4. Operation must be in “AUTO”
mode or “MANUAL” mode.