4-
203
4
Operation
12. “SYSTEM” mode
12.3.4.2 Setting the double-carrier parameters
[Procedure]
1) Press the
F 4
(W.CARRIER) in "SYSTEM>OPTION" mode.
Fig. 4-12-85 Double-carrier parameter setting (1)
SYSTEM
>OPTION>W.CARRIER
V8.58
1.Stroke[mm]
0.00
2.Carrier1
M1
3.Carrier2
M2
4.Control mode
OFF
EDIT
JUMP
Valid keys and submenu descriptions in this mode are shown below.
F1
F2
Cursor key
(
↑
/
↓
)
Valid keys
EDIT
JUMP
Menu
Function
Edits the parameter being selected with the cursor.
Jumps to the specified point number.
Moves the cursor up and down.
1. Stroke setting
[Procedure]
1) Select "1. Stroke [mm]" and press
F 1
(EDIT).
Fig. 4-12-86 Double-carrier parameter setting (2)
SYSTEM
>OPTION>W.CARRIER>EDIT
V8.58
1.Stroke[mm]
0.00
2.Carrier1
M1
3.Carrier2
M2
4.Control mode
OFF
[1- ] Enter >650.00
n
NOTE
The stroke corresponds to the current
position of one carrier that was moved
from its origin position, to a point
closest to the other carrier remaining
at its origin position after return-to-
origin.
Содержание RCX141
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E93 Ver 2 02 RCX141 ...
Страница 2: ......
Страница 16: ...viii MEMO ...
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 34: ...2 8 MEMO ...
Страница 36: ...MEMO ...
Страница 54: ...3 18 MEMO ...
Страница 290: ...4 232 MEMO ...
Страница 292: ...MEMO ...
Страница 316: ...5 24 MEMO ...
Страница 318: ...MEMO ...
Страница 326: ...6 8 MEMO ...
Страница 328: ...MEMO ...
Страница 338: ...7 10 MEMO ...
Страница 340: ...MEMO ...
Страница 346: ...MEMO ...
Страница 401: ...MEMO ...