4-
169
4
Operation
12. “SYSTEM” mode
8. DI noise filter/SCANMD
This parameter sets whether to cancel external input signals (dedicated input signals,
general-purpose input signals) that might appear like noise in the form of short pulses.
When this parameter is set to "VALID", the on and off periods of input signals must be
longer than 25msec since the controller does not respond to any signal input shorter
than 25msec. This prevents the controller from responding to noise inputs.
[Procedure]
1) Select “8. DI noise filter” in “SYSTEM>PARAM>OTHERS” mode.
2) Press the
F 1
(EDIT) key.
The function key menu changes.
Fig. 4-12-37 Setting “DI noise filter”
SYSTEM
>PARAM>OTHERS V8.30
4.DO cond. on EMG
HOLD
5.Watch on STD.DIO DC24V
VALID
6.Incremental Mode control
INVALID
8.DI noise filter
VALID
7.IO cmd (DI05) on STD.DIO
INVALID
INVALID
VALID
3) Press the
F 1
(INVALID) or
F 2
(VALID) key.
4) Press the
ESC
key to quit the edit mode.
Содержание RCX141
Страница 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E93 Ver 2 02 RCX141 ...
Страница 2: ......
Страница 16: ...viii MEMO ...
Страница 18: ...MEMO ...
Страница 24: ...1 6 MEMO ...
Страница 26: ...MEMO ...
Страница 34: ...2 8 MEMO ...
Страница 36: ...MEMO ...
Страница 54: ...3 18 MEMO ...
Страница 290: ...4 232 MEMO ...
Страница 292: ...MEMO ...
Страница 316: ...5 24 MEMO ...
Страница 318: ...MEMO ...
Страница 326: ...6 8 MEMO ...
Страница 328: ...MEMO ...
Страница 338: ...7 10 MEMO ...
Страница 340: ...MEMO ...
Страница 346: ...MEMO ...
Страница 401: ...MEMO ...