151
7.2 Analysis of alarm types
DS5 alarm code format is E-XX□, “XX” means main type, “□” means sub-type.
Type
Code
Description
Reasons
Solutions
EE
EE
1
EEEE
1
Communication
error between
panel and CPU
(1) Voltage fluctuation
of power supply is
large, and low voltage
leads to failure of panel
refresh; (2) Damage of
panel program
(1) Stable power supply to ensure
the stability of power supply
voltage.
(2) after repower on the driver, if
the alarm cannot be removed,
please contact the agent or the
manufacturer.
2
EEEE
2
3
EEEE
3
4
EEEE
4
01
0
E-010
Firmware version
mismatch
Downloaded firmware
version error
Please contact the agent or the
manufacturer
3
E-013
FPGA
loading
error
①
program damaged
②
device damaged
Please contact the agent or the
manufacturer
4
E-014
FPGA
Access
error
(1) Program damage
(2) Device damage
(3)
serious
external
interference
Please contact the agent or the
manufacturer
5
E-015
Program running
error
Program damage
Please contact the agent or the
manufacturer
6
E-016 Hardware error
①
program damaged
②
hardware damaged
③
Excessive intensity
of external interference
①
Check the input voltage,
whether the input phase is
missing or the supply voltage is
too low
②
Contact
agent
or
manufacturer
7
E-017
Processor
Running Timeout
Program damage
Please contact the agent or the
manufacturer
9
E-019
System password
error
Program damage
Please contact the agent or the
manufacturer
02
0
E-020
Parameter loading
error
Failure of parameter
self-checking
Re-energizing can restore default
parameters, if there are repeated
problems, please contact the
agent or manufacturer.
1
E-021
Parameter range
beyond limit
Setting values are not
within the prescribed
range
Check parameters and reset them
2
E-022
Parameter
conflict
Conflict of TREF or
VREF
Function
Settings
P0-01=4, P3-00 set to 1 will
alarm
3
E-023
Sampling channel
setting error
Error setting of custom
output trigger channel
or
data
monitoring
channel
Check that the settings are
correct
4
E-024 parameter lost
Low voltage of power
grid
(1) If it is single-phase 220V
power supply, please connect L1
and L3.
(2) show E-024 immediately
after power failure
(3) Resetting parameters
5
E-025 Erase
FLASH
error
Abnormal
parameter
preservation
during
power failure
please contact the agent or the
manufacturer
6
E-026 Initialization FLASH
error
Power
supply
instability of FLASH
chip
please contact the agent or the
manufacturer
Содержание DS5F Series
Страница 1: ...DS5F series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 02 20200217 2 3 ...
Страница 2: ......
Страница 41: ...39 3 2 5 Encoder feedback output signal Servo driver differential to collector upper device ...
Страница 124: ...122 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 202: ...200 Appendix 9 Torque speed characteristic curve ...
Страница 203: ...201 ...
Страница 204: ...202 ...