5.8 Encoder ABZ phase frequency division output
The servo driver outputs the differential signal through the frequency division output circuit. It can
provide position signal for the control of the upper computer or pulse signal for the driven servo, so as
to realize the follow-up control of the master-slave shaft.
1. Encoder frequency division output specification
Terminal
name
Terminal pin no.
Terminal function
Hardware version 3131 and
earlier [CN1]
Hardware version 3131 and
later [CN0]
OA+
1
35
A phase frequency
division output
OA-
2
36
OB+
3
37
B phase frequency
division output
OB-
4
38
OZ+
5
39
Z phase frequency
division output
OZ-
9
40
2. Wiring diagram
JS-IDC-ABZ
GND
A+
A-
B+
B-
Z+
Z-
COM
A
B
Z
24V
Input
Output
Switch
power
supply
N
COM
X1
X3
X5
X7
L
FG
X0
X2
X4
X6
0V
Y0
Y2
COM1
Y5
Y7
24V
COM0
Y1
Y3
Y4
Y6
AO+
AO-
BO+
BO-
ZO+
ZO-
3. Encoder feedback pulse number per turn
P0-18
Set the number of feedback pulses per turn of encoder (low-order position)
Unit
Default
setting
Range
Suitable
mode
Modify
Effective
1
0
0~9999
All
Servo OFF
At once
P0-19
Set the number of feedback pulses per turn of encoder (high-order position)
Unit
Default
setting
Range
Suitable mode
Modify
Effective
10000
1
0~9999
All
Servo OFF
At once
Note:
(1) Output pulses per turn: P0-19 * 10000 + P0-18. It can be any positive integer.
(2) Encoder feedback will be output from CN0 port (hardware version 3131 and earlier encoder
feedback output at CN1 port). It is recommended that the lower computer accept pulse with AB phase
counter.
If AB phase counting is adopted, the counting value of motor rotation for one turn is 4 times of the
set pulse number per turn of encoder (P0-18 + P0-19 * 10000).
(3) The pulse output frequency of each phase shall not exceed 1MHz, and the number of pulses per
cycle can be set in cooperation with the z-phase pulse estimation formula.
Example: Assume the actual speed of motor is 3000rpm,
28.8 1
3000×ppr 10
×2
≥
6
ppr
≤
18720
, then
the setting of pulse number feedback per turn shall not exceed 18720.
1 1
× ppr 10
≥
6
ppr
≤
20000
n
60
, then
the setting of pulse number feedback per turn shall not exceed 20000.
(4) Assuming that the number of feedback pulses per turn is 10, the output signals of phase A (PAO)
Содержание DS5F Series
Страница 1: ...DS5F series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 02 20200217 2 3 ...
Страница 2: ......
Страница 41: ...39 3 2 5 Encoder feedback output signal Servo driver differential to collector upper device ...
Страница 124: ...122 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 202: ...200 Appendix 9 Torque speed characteristic curve ...
Страница 203: ...201 ...
Страница 204: ...202 ...